5台3750堆叠。
------------------ show switch detail ------------------
Switch/Stack Mac Address : 001d.a224.0400
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 001d.a224.0400 14 0 Ready
2 Member 001d.a23c.ff80 12 0 Ready
3 Member 001d.e516.f880 10 0 Ready
4 Member 001d.a223.fb00 8 0 Ready
5 Member 001d.a23c.df80 6 0 Ready
Stack Port Status Neighbors
Switch# Port 1 Port 2 Port 1 Port 2
--------------------------------------------------------
1 Ok Ok 2 5
2 Ok Ok 3 1
3 Ok Ok 4 2
4 Ok Ok 5 3
5 Ok Ok 1 4
问题:
1. 其中一台3750的多个端口POE失效。
2. POE Failure的端口可以正常转发数据。
3. 以下是客户的邮件:
1. There is no information desplayed on the LCD Screen of the IP Phone. As far as i know, the headset/mute/spraker buttons on the phone will flash in turn when connnected to the good port. But there is no response when we connected the good phone directly to the 7 ports.
2. So far there are 7 ports on this switch can not supply the IP Phones.
P14/15/16/17/43/45/46.
3. The IP Phones/RJ-45 Lines/config file of the switch are all well.
解决问题:
让客户采集必要的POE的相关信息:
1\ Captrue the information for "show int f3/0/14 transceiver properties" and "show power inline f3/0/14 " when insert the ip phone into the port.
2\ Captrue the information for "show int fx/0/x transceiver properties" and "show power inline fx/0/x " for good port.
以下是信息:
#show int f3/0/14 transceiver properties
Diagnostic Monitoring is not implemented.
Name : Fa3/0/14
Administrative Speed: auto
Administrative Duplex: auto
Administrative Auto-MDIX: on
Administrative Power Inline: enable
Operational Speed: auto
Operational Duplex: auto
Operational Auto-MDIX: on
Media Type: 10/100BaseTX
#show power inline f3/0/14
Interface Admin Oper Power Device Class Max
(Watts)
--------- ------ ---------- ------- -------------------
Fa3/0/14 auto off 0.0 n/a n/a 15.4
Interface AdminPowerMax AdminConsumption
(Watts) (Watts)
---------- --------------- --------------------
Fa3/0/14 15.4 15.4
++++++++++++++++++++++++++++++++++++++++
#sh interfaces f3/0/13 transceiver properties
Diagnostic Monitoring is not implemented.
Name : Fa3/0/13
Administrative Speed: auto
Administrative Duplex: auto
Administrative Auto-MDIX: on
Administrative Power Inline: enable
Operational Speed: 100
Operational Duplex: full
Operational Auto-MDIX: on
Media Type: 10/100BaseTX
#sh power inline f3/0/13
Interface Admin Oper Power Device Class Max
(Watts)
--------- ------ ---------- ------- -------------------
Fa3/0/13 auto on 6.3 IP Phone 7940 n/a 15.4
Interface AdminPowerMax AdminConsumption
(Watts) (Watts)
---------- --------------- --------------------
Fa3/0/13 15.4 15.4
POE端口供电问题,可能供电芯片损坏,更换备件。
客户解决中的问题:
对于堆叠的交换机,如何进行割接更换?
Follow information is step for cut over:
1\ Backup the Master config to flash.
#copy run flash
2\ Upgrade the IOS for RMA part.
#archive upload-sw tftp://172.16.2.155/c3750-ipbasek9-mz.122-40.SE.tar
!--- upload the ios to tftp
#archive download-sw /leave-old-sw /reload tftp://172.16.2.155/c3750-ipbasek9-mz.122-40.SE.tar
!--- download-sw Download a new copy of software from a server
!--- /leave-old-sw Leave old sw installed after successful sw upgrade
!--- /reload Reload system (if no unsaved config changes) after successful sw upgrade
3\ Change the New part SW priority:
Switch#sh sw
Switch/Stack Mac Address : 0016.9de7.ea00
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 0016.9de7.ea00 10 0 Ready
Switch#config ter
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#sw 1 pri 1
Changing the Switch Priority of Switch Number 1 to 1
Do you want to continue?[confirm]
New Priority has been set successfully
Switch(config)#end
Switch#
Switch#sh sw
Switch/Stack Mac Address : 0016.9de7.ea00
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 0016.9de7.ea00 1 0 Ready
#wr
4\ Power down and join the stack.
5\ Power on.
关于堆叠的一些基础知识:
在LAB中,3台3750堆叠:
1. 加台新设备,如果带电加,可能会导致其他设备重启,这样如果新SW优先级大,他会同步其他两台设备的配置。不加电入网,不会影响堆叠:
Switch#sh sw
Switch/Stack Mac Address : 0016.9de7.ea00
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 0016.9de7.ea00 10 0 Ready
2 Member 0016.9df2.6480 2 0 Ready
3 Member 0012.4306.6380 14 0 Ready
2. 堆叠成功后,配置及文件名都被同步,3台设备的Console口信息都是相同的,而且均是Master的。
3. 上面的1,2,3是逻辑的,所以不能从这上面判断现实中的交换机(比如说1,有可能在现实中是中间的交换机)。所以在排除故障是,只能根据序列号来判定具体是哪台交换机故障。
4. 把3下架后,console进去:
c3750-2#sh sw
Switch/Stack Mac Address : 0012.4306.6380
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
1 Member 0000.0000.0000 0 0 Provisioned
2 Member 0000.0000.0000 0 0 Provisioned
*3 Master 0012.4306.6380 3 0 Ready
配置及端口信息仍然存在。
在另外两台堆叠SW上:
c3750-2#sh sw
Switch/Stack Mac Address : 0016.9de7.ea00
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 0016.9de7.ea00 10 0 Ready
2 Member 0016.9df2.6480 2 0 Ready
3 Member 0000.0000.0000 0 0 Provisioned
没有评论: